IMPEKTRA IMPEKLub Auto

Management System for Automatic Lubrication

Make your automatic lubrication process safer and traceable.

A pump signal is not the same as actual flow at the lubrication point.

The critical distinction: Did the pump run, or did the grease actually reach the target point?

Why it matters

  • A running pump alone does not prove that grease is reaching every critical point.
  • Blockages, leaks, or insufficient supply may go unnoticed until they put production at risk.

01 · Digital Flow Meter

Lubrication Backed by Verified Data, Not Assumptions

IMPEKLub Digital Flow Meter: a digital flow verification device with a black housing and a stainless-steel base

IMPEKLub Digital Flow Meter

IMPEKLub Auto integrates a digital flow verification device into your existing automatic lubrication infrastructure. The result:

  • Grease flow at the main outlet and on critical lines is verified in real time.
  • Flow alarms and historical records are monitored on a central platform.
  • Your maintenance team can spot anomalies before equipment fails.
  • Flow Verification

    Digitally verifies and records grease as it passes through the line.

  • Real-Time Monitoring

    Sends flow data to the central platform.

  • Flow Alarms

    Flags interrupted flow or a missed lubrication cycle.

  • Retrofit-Ready

    Installs in existing lines once a technical assessment confirms suitability.

02 · How It Works

Safer, More Traceable Automatic Lubrication Systems

Set up your plant and its automatic lubrication system once. From then on, monitor every lubrication event in the IMPEKLub Portal and make your lubrication process safer and more efficient.

  1. 01 IMPEKLub Portal

    Build a Digital Twin of Your Lubrication Program

    The digital flow verification device is integrated into your existing automatic lubrication infrastructure. Every lubrication point in the plant is registered in the IMPEKLub Portal and assigned a digital ID.

    • Equipment and location
    • Lubricant type
    • Specified amount
    • Lubrication interval
    • Lubrication history
  2. 02 Digital Flow Meter

    Measure and Verify

    The Digital Flow Meter sends its field measurements straight to the IMPEKLub Portal. For every lubrication point in the system, that means:

    • Real-time verification of grease flow at the main outlet and on critical lines
    • Central monitoring of flow alarms and historical records
    • An early view of anomalies for your maintenance team, before equipment fails
  3. 03 IMPEKLub Portal

    Monitor, Measure, Report

    Field data flows into the IMPEKLub Portal, giving managers full visibility and reporting so they can:

    • Track open, completed, and overdue work orders
    • Review the complete lubrication history of any equipment or lubrication point
    • Catch deviations before they turn into failures
    • Measure lubrication performance on real data, not assumptions
    • Improve planning based on actual lubricant consumption and field data

System Architecture and Measuring Points

A meter at the main outlet confirms the system is running; meters on critical branch lines confirm that grease is moving toward the target.

Measuring-point diagram: Digital Flow Meters at the main outlet of an automatic lubrication pump, on the branch lines downstream of the distributor block, and at the equipment inlets; the branch line with no flow is marked in red
  1. 01 Main outlet Actual grease output from the pump
  2. 02 Critical branch line Selected line downstream of the distributor block
  3. 03 Equipment inlet Verification closest to the target

Central Monitoring and Response Workflow

Field data, alarms, and close-out records are managed in a single workflow.

  1. 1 Flow event
  2. 2 Alarm
  3. 3 Field check
  4. 4 Intervention
  5. 5 Re-verification

What managers get: a timestamped flow log, alarm history, and intervention close-out records

IMPEKLub Portal dashboard showing daily, weekly, and monthly lubricant consumption summaries, charts of grease consumption and wasted lubricant, and a task list
IMPEKLub Portal: every lubrication point on one screen

03 · Verified Lubrication

Point-Level Verification, End-to-End Accountability

A significant share of premature bearing failures is linked to under-lubrication, over-lubrication, and contamination. Yet in many plants, lubrication is still not tracked digitally. This lack of visibility makes it impossible to verify what actually happens at each lubrication point.

What unverifiable lubrication costs your plant:

  • Unplanned downtime and lost production. Production lines brought to a halt by preventable bearing and equipment failures.
  • Missed and incorrect tasks. Points that are overlooked, serviced late, or given the wrong lubricant under demanding production schedules.
  • Under- or over-lubrication. Uncontrolled dosing that wastes lubricant, blows out seals, and damages equipment.
  • Lack of reliable data. No evidence-based history to support root cause analysis, maintenance planning, or external audits.

IMPEKLub

Reliability Starts at the Lubrication Point

IMPEKLub closes the full lubrication loop, from planning to execution and from verification to analysis. Every lubrication point has a unique digital ID, every task is measured precisely, and every application is recorded in real time.

Flow Anomalies and Maintenance Actions

Field conditionWhat the Digital Flow Meter showsPossible interpretationMaintenance action
Pump not running or no supply No flow at main outlet Possible pump, reservoir, or supply line issue Check supply source and pump cycle
Line blocked after distributor No flow in affected branch Possible blockage in branch line or connection Inspect line and distributor outlet
Line broken or leaking Expected flow pattern changes Grease may not be reaching target point Check pipes, fittings, and connections
Insufficient or irregular supply Flow data deviates from cycle Possible pump cycle or distribution issue Review trend alongside field findings

The Digital Flow Meter flags the flow anomaly. The maintenance team confirms the root cause with a field check.

Scope and Limits

What the Digital Flow Meter Does

  • Verifies grease flow
  • Makes flow interruptions visible
  • Generates alarms and historical records
  • Provides central monitoring

What the Digital Flow Meter Does Not Do on Its Own

  • Does not diagnose mechanical health
  • Does not confirm the root cause without a field check
  • Does not automatically compensate for incorrect installation
  • Does not replace a technical suitability assessment

04 · System Components

One Connected System. One Record Everyone Trusts.

The IMPEKLub architecture is built on three core components that seamlessly connect hands-on work in the field with central digital management:

  • Digital Flow Meters on four branch lines running from a distributor block to bearing housings; the line with no flow is shown in red

    Digital Identification and Physical Verification

    Digital Identification

    Gives every lubrication point a unique digital ID.

    • Positively identifies the equipment and lubrication point in the field.
    • Links the point to its specifications: required lubricant type, target amount, and interval.
  • Digital Flow Meter connected to the main outlet line of an automatic lubrication pump

    Device

    Digital Flow Meter

    Delivers high-precision measurement and verification at the lubrication point.

    • Flow Verification Digitally verifies and records grease as it passes through the line.
    • Real-Time Monitoring Sends flow data to the central platform.
    • Flow Alarms Flags interrupted flow or a missed lubrication cycle.
    • Retrofit-Ready Installs in existing lines once a technical assessment confirms suitability.
  • IMPEKLub Portal dashboard open on a laptop in a plant maintenance office

    Portal

    IMPEKLub Management Platform

    Field data, alarms, and close-out records are managed in a single workflow.

    • Flow Event: Continuous Data Tracking Any deviation outside the system’s normal operating parameters is logged digitally the moment it occurs.
    • Alarm: Instant Alert and Prioritization The system raises an alarm automatically when a critical threshold is exceeded or a flow interruption is detected.
    • Field Check: Targeted Diagnosis Location and fault-code data in the platform direct the field team straight to the right point.
    • Re-Verification: Safe Close-Out After the intervention, the system is brought back online and sensor data confirms that lubrication flow is back to normal.
    • Reporting and Management Generates deviation alerts, complete equipment lubrication histories, and reports ready for internal and external audits.

05 · Application Areas

Typical Applications

The final scope is set based on your existing automatic lubrication infrastructure, failure history, and equipment criticality.

  • Conveyor and transfer systems
  • Fan, pump, and motor bearings
  • Crushers and heavy-duty power transmission equipment
  • Open gear, kiln, and mill applications
  • High-temperature, dusty, or hard-to-reach points

The IMPEKLub family

Technician holding the IMPEKLub Smart Handheld Flow Meter

IMPEKLub Manual

Management System for Manual Lubrication

A smart lubrication solution for industrial plants that digitally plans, manages, and field-verifies manual greasing operations. It makes sure the right equipment is greased at the right time, in the right amount, by authorized personnel, so the entire operation is traceable end to end.

IMPEKLub Auto

Every Lubrication Point. Verified.

Let’s set up a call about your plant, or run an ROI analysis on your own field data.