A pump signal is not the same as actual flow at the lubrication point.
The critical distinction: Did the pump run, or did the grease actually reach the target point?
Why it matters
A running pump alone does not prove that grease is reaching every critical point.
Blockages, leaks, or insufficient supply may go unnoticed until they put production at risk.
01 · Digital Flow Meter
Lubrication Backed by Verified Data, Not Assumptions
IMPEKLub Digital Flow Meter
IMPEKLub Auto integrates a digital flow verification device into your existing automatic lubrication infrastructure. The result:
Grease flow at the main outlet and on critical lines is verified in real time.
Flow alarms and historical records are monitored on a central platform.
Your maintenance team can spot anomalies before equipment fails.
Flow Verification
Digitally verifies and records grease as it passes through the line.
Real-Time Monitoring
Sends flow data to the central platform.
Flow Alarms
Flags interrupted flow or a missed lubrication cycle.
Retrofit-Ready
Installs in existing lines once a technical assessment confirms suitability.
02 · How It Works
Safer, More Traceable Automatic Lubrication Systems
Set up your plant and its automatic lubrication system once. From then on, monitor every lubrication event in the IMPEKLub Portal and make your lubrication process safer and more efficient.
01IMPEKLub Portal
Build a Digital Twin of Your Lubrication Program
The digital flow verification device is integrated into your existing automatic lubrication infrastructure. Every lubrication point in the plant is registered in the IMPEKLub Portal and assigned a digital ID.
Equipment and location
Lubricant type
Specified amount
Lubrication interval
Lubrication history
record →
02Digital Flow Meter
Measure and Verify
The Digital Flow Meter sends its field measurements straight to the IMPEKLub Portal. For every lubrication point in the system, that means:
Real-time verification of grease flow at the main outlet and on critical lines
Central monitoring of flow alarms and historical records
An early view of anomalies for your maintenance team, before equipment fails
data →
03IMPEKLub Portal
Monitor, Measure, Report
Field data flows into the IMPEKLub Portal, giving managers full visibility and reporting so they can:
Track open, completed, and overdue work orders
Review the complete lubrication history of any equipment or lubrication point
Catch deviations before they turn into failures
Measure lubrication performance on real data, not assumptions
Improve planning based on actual lubricant consumption and field data
System Architecture and Measuring Points
A meter at the main outlet confirms the system is running; meters on critical branch lines confirm that grease is moving toward the target.
01Main outletActual grease output from the pump
02Critical branch lineSelected line downstream of the distributor block
03Equipment inletVerification closest to the target
Central Monitoring and Response Workflow
Field data, alarms, and close-out records are managed in a single workflow.
1 Flow event
2 Alarm
3 Field check
4 Intervention
5 Re-verification
What managers get: a timestamped flow log, alarm history, and intervention close-out records
Dashboard
IMPEKLub Portal: every lubrication point on one screen
A significant share of premature bearing failures is linked to under-lubrication, over-lubrication, and contamination. Yet in many plants, lubrication is still not tracked digitally. This lack of visibility makes it impossible to verify what actually happens at each lubrication point.
What unverifiable lubrication costs your plant:
Unplanned downtime and lost production. Production lines brought to a halt by preventable bearing and equipment failures.
Missed and incorrect tasks. Points that are overlooked, serviced late, or given the wrong lubricant under demanding production schedules.
Under- or over-lubrication. Uncontrolled dosing that wastes lubricant, blows out seals, and damages equipment.
Lack of reliable data. No evidence-based history to support root cause analysis, maintenance planning, or external audits.
IMPEKLub
Reliability Starts at the Lubrication Point
IMPEKLub closes the full lubrication loop, from planning to execution and from verification to analysis. Every lubrication point has a unique digital ID, every task is measured precisely, and every application is recorded in real time.
Flow Anomalies and Maintenance Actions
Field condition
What the Digital Flow Meter shows
Possible interpretation
Maintenance action
Pump not running or no supply
No flow at main outlet
Possible pump, reservoir, or supply line issue
Check supply source and pump cycle
Line blocked after distributor
No flow in affected branch
Possible blockage in branch line or connection
Inspect line and distributor outlet
Line broken or leaking
Expected flow pattern changes
Grease may not be reaching target point
Check pipes, fittings, and connections
Insufficient or irregular supply
Flow data deviates from cycle
Possible pump cycle or distribution issue
Review trend alongside field findings
The Digital Flow Meter flags the flow anomaly. The maintenance team confirms the root cause with a field check.
Scope and Limits
What the Digital Flow Meter Does
Verifies grease flow
Makes flow interruptions visible
Generates alarms and historical records
Provides central monitoring
What the Digital Flow Meter Does Not Do on Its Own
Does not diagnose mechanical health
Does not confirm the root cause without a field check
Does not automatically compensate for incorrect installation
Does not replace a technical suitability assessment
04 · System Components
One Connected System. One Record Everyone Trusts.
The IMPEKLub architecture is built on three core components that seamlessly connect hands-on work in the field with central digital management:
Digital Identification and Physical Verification
Digital Identification
Gives every lubrication point a unique digital ID.
Positively identifies the equipment and lubrication point in the field.
Links the point to its specifications: required lubricant type, target amount, and interval.
Device
Digital Flow Meter
Delivers high-precision measurement and verification at the lubrication point.
Flow VerificationDigitally verifies and records grease as it passes through the line.
Real-Time MonitoringSends flow data to the central platform.
Flow AlarmsFlags interrupted flow or a missed lubrication cycle.
Retrofit-ReadyInstalls in existing lines once a technical assessment confirms suitability.
Portal
IMPEKLub Management Platform
Field data, alarms, and close-out records are managed in a single workflow.
Flow Event: Continuous Data TrackingAny deviation outside the system’s normal operating parameters is logged digitally the moment it occurs.
Alarm: Instant Alert and PrioritizationThe system raises an alarm automatically when a critical threshold is exceeded or a flow interruption is detected.
Field Check: Targeted DiagnosisLocation and fault-code data in the platform direct the field team straight to the right point.
Re-Verification: Safe Close-OutAfter the intervention, the system is brought back online and sensor data confirms that lubrication flow is back to normal.
Reporting and ManagementGenerates deviation alerts, complete equipment lubrication histories, and reports ready for internal and external audits.
05 · Application Areas
Typical Applications
The final scope is set based on your existing automatic lubrication infrastructure, failure history, and equipment criticality.
Conveyor and transfer systems
Fan, pump, and motor bearings
Crushers and heavy-duty power transmission equipment
A smart lubrication solution for industrial plants that digitally plans, manages, and field-verifies manual greasing operations. It makes sure the right equipment is greased at the right time, in the right amount, by authorized personnel, so the entire operation is traceable end to end.
View page
IMPEKLub Auto
Every Lubrication Point. Verified.
Let’s set up a call about your plant, or run an ROI analysis on your own field data.